920-0046 A
STAC6-C Quick Setup Guide
Step 2 - CANOpen Setup
Connect to CAN network.
Applied Motion Products STAC6-C drives use a four-pin
spring connector, that conforms to the DR303 specication.
The connector should be wired in a daisy-chain conguration
with a 120 Ohm resistor used to terminate each end.
Switch Setting Resultant Bit Rate
0 1 Mbps
1 800kbps
2 500 kbps
3 250 kbps
4 125 kbps
5 50 kbps
6 20 kbps
7 12.5 kbps
8
n/a
9 n/a
Bit Rate Table
Connect the drive to your PC using the RS-232 programming cable.
Download and install STAC Congurator™ software, available at www.applied-motion.com.
Launch the software by clicking Start/Programs/Applied Motion Products/STAC Congurator
Step 3 - Configuration
Apply power to the drive.
Use the STAC Congurator™ to set up the motor current, load iner-
tia, limit switches, encoder functionality (if applicable) and Node ID.
The STAC Congurator™ includes a self test option (under the Drive menu)
to verify that the STAC6-C and motor are correctly wired and congured.
When conguration is complete, exit STAC Congurator™.
The drive will automatically switch to CANOpen Mode.
If you have any questions or comments, please call Applied Motion Products
Customer Support (800)525-1609 or visit us online at www.applied-motion.com.
404 Westridge Dr.
Watsonville, CA 95076
Tel: 800-525-1609
Fax: 831-761 -6544
www.applied-motion.com
If you have any questions or comments,
please call Applied Motion Products
Customer Support: (800) 525-1609,
or visit us online at www.applied-motion.com.
Set BitRate, Node ID
CANOpen Bitrate - AMP CANOpen drives have three set-
tings, one for Bit Rate and two for Node ID. The Bit Rate
is congured using an eight-position switch. See Bit Rate
table for the Bit Rate settings. The Node ID is congured
using a sixteen position switch to set up the lower four bits
of the Node ID. The upper three bits of the Node ID are set
using the STAC Congurator™. Valid ranges for the Node
ID are 0x01 through 0x7F. Node ID 0x00 is reserved in ac-
cordance with the DS301 specication.
Note: The Node ID and Bit Rate are captured only after a
power cycle, or after a network reset command has been
sent. Changing the switches while the drive is powered on
will NOT change the Node ID or Bit Rate until one of these
conditions has been met.
GND
CAN_L
SHLD
CAN_H