29
BLuAC5 S/Q Hardware manual
920-0049 Rev. C
12/8/2014
Wiring a controller with differential output as a singled ended input
If both inputs are to be used for different purposes differential outputs can be connected to a
single input:
Wiring a controller with differential output to differential input
Care must be taken here to establish a good ground connection. The system ground in this
case can be used for the cable shield.
Wiring a potentiometer to a singled ended input
The +5Volt power supply from the servo drive should be used to minimize ground and voltage
difference effect.