STR2 Hardware Manual
920-0059B
1/30/2014
Step 4: Load Inertia
e STR drives include anti-resonance and electronic damping features which greatly improve
motor performance. To perform optimally, the drive must understand the electromechanical
characteristics of the motor and load. Most of this is done automatically when you select the
motor using switches B1, B2 and B3. To further enhance performance, you must set switch B4
to indicate the approximate inertia ratio of the load and motor. e ranges are 0 to 4X and 5 to
10X. e motors table shown in Step 1 of this section include the rotor inertia of each motor.
Please divide the load inertia by the rotor inertia to determine the ratio, then set switch B4 as
shown. For assistance in calculating the load inertia of your application contact our Applications
department.
Step 5: Step Size
e STR2 requires a source of step pulses to command motion. is may be a PLC, an indexer,
a motion controller or another type of device. e only requirement is that the device be able
to produce step pulses whose frequency is in proportion to the desired motor speed, and be
able to smoothly ramp the step speed up and down to produce smooth motor acceleration
and deceleration.
Smaller step sizes result in smoother motion and more precise speed, but also require a
higher step pulse frequency to achieve maximum speed. e smallest step size of the STR2 is
1/20,000th of a motor turn. To command a motor speed of 50 revolutions per second (3000
rpm) the step pulses frequency must be 50 x 20,000 = 1 MHz. Many motion devices, especially
PLCs cannot provide step pulses at such a high speed. If so, the drive must be set for a lower
number of steps per revolution. Six dierent seings are provided in the STR2 drive, as shown
in the table on the next page.
4
5-10X
4
0-4X