e actual temperature of the motor depends on how much heat is conducted, convected or
radiated out of it. Our measurements were made in a 40°C (104°F) environment with the motor
mounted to an aluminum plate sized to provide a surface area consistent with the motor power
dissipation. Your results may vary.
STR4 Maximum Motor Duty Cycle
Motor Connection
Drive Current
Amps, peak of
sine
Max Duty Cycle at 40°C Ambient
24VDC 48VDC
HT17-068 parallel 1.6 100% see chart
HT17-071 parallel 2 100% see chart
HT17-075 parallel 2 see chart see chart
HT17-268 parallel 1.6 100% see chart
HT17-271 parallel 2 100% see chart
HT17-275 parallel 2 100% see chart
HT17-278 parallel 2.4 100% see chart
HT23-394 parallel 3.4 100% see chart
HT23-398 parallel 4.5 100% see chart
HT23-401 parallel 4.5 100% see chart
HT23-594 parallel 3.4 100% see chart
HT23-598 parallel 4.5 100% see chart
HT23-601 parallel 4.5 100% see chart
HT24-100 4 leads 3.36 100% 100%
HT24-105 4 leads 4.5 100% see chart
HT24-108 4 leads 4.5 100% see chart
HT34-485 series 4.5 100% 100%
HT34-486 series 4.5 see chart see chart
HT34-504 series 3.816 100% 100%
HT34-505 series 3.816 100% 100%