Applied-motion SWM24IP-3EE Manuel d'utilisateur Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
CONTROLLER: -S, -Q, -IP Models
IN1 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CW limit, general purpose input.
IN2 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CCW limit, general purpose input.
IN3 Optically isolated, 5-24 V, 8-12 mA.
Function: home sensor, general purpose input.
OUT Optically isolated, 30V, 40mA MAX. open emitter/collector.
Function: fault, motion, alarm, tach or general purpose
30