LED Error Codes
Status LED SWM
e SWM24 drive+motor includes a red/green LED to indicate status. When the motor is enabled, the LED ashes green
slowly. When the green LED is solid, the motor is disabled.
Errors are indicated by combinations of red and green “ashes” as follows:
Code Error
solid green no alarm, motor disabled
flashing green no alarm, motor enabled
fast green Q program running
1 red, 1 green motor disabled after a stall condition occurred
1 red, 2 green move attempted while drive disabled
2 red, 1 green ccw limit
2 red, 2 green cw limit
3 red, 1 green drive overheating
3 red, 2 green internal voltage out of range
3 red, 3 green blank Q segment
4 red, 1 green power supply overvoltage
4 red, 2 green power supply undervoltage
4 red, 3 green flash memory backup error
5 red, 1 green over current / short circuit
5 red, 2 green I/O occupied
6 red, 1 green open motor winding
6 red, 2 green bad encoder signal
7 red, 1 green serial communication error
7 red, 2 green flash memory error