Eight lead motors can also be connected in two ways: series and parallel. As with six lead motors, series
operation gives you less torque at high speeds, but may result in lower motor losses and less heating. In
series operation, the motor should be operated at 30% less than the unipolar rated current. The wiring
diagrams for eight lead motors are shown below.
A+
A–
B+ B–
8
lead
motor
8 Leads Series Connected 8 Leads Parallel Connected
A+
A–
B+
B–
8
lead
motor
Orange
Org/Wht
Blk/Wht
Black
Red
Red/
Wht
Yel/
Wht
Yellow
Orange
Org/
Wht
Blk/Wht
Black
Red
Red/Wht
Yel/
Wht
Yel
low