Applied-motion STM23R-2ND Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
12
STM23R Hardware Manual
920-0056C
5/5/2015
Regeneration
If you plan to use a regulated power supply you may encounter a problem with regeneration. If you rapidly
decelerate a load from a high speed, much of the kinetic energy of that load is transferred back to the power
supply. is can trip the overvoltage protection of a switching power supply, causing it to shut down. Unregu-
lated power supplies are beer because they generally do not have overvoltage protection and have large
capacitors for storing energy coming back from the drive. ey are also less expensive. See previous section on
Connecting the Power Supply
for details on the RC-050 regeneration clamp.
1.50
2.00
2.50
3.00
3.50
Amps
STM23R-3 70V Power Supply Current
Full Load
No Load
0.00
0.50
1.00
0 10 20 30 40 50
Speed (RPS)